Image Alt

Equipment Profiles

NON-RADIOACTIVE VIS MULTIPHASE FLOW METER

Real-time reservoir management underground gas storage fields:
Bi-directional measurements Water-in gas minimization Radioactive-free Continuous, real-time measurement Based on conventional instrumentation Compact size
80 – 100% GVF
operating range
Self-calibrating

2,000PSI 3-PH SEPARATOR
  • ASME Section VIII Division 1 Latest Rev.
  • NACE MR-0175, ANSI B13.1, ASME Section IX
  • 2,000PSI 3-PH Multi relief and Dual Gas Metering System
  • Automatic control valve on the gas outlet line maintains a constant pressure in the vessel
30,000BPD INDUCED GAS FLOTATION PRODUCED WATER TREATMENT SYSTEM
  • Complete with Carbon Polishing skid
  • Fully automated
  • Redundant pumping system – recycle, transfer, evacuation
  • Up to 500ppm inlet effluent concentration
  • Up to 50ppm inlet solid concentration
  • Less than 10ppm outlet water quality
1,440PSI 72” X 20’ | 66” X 20’ LONG HORIZONTAL ASME-U STAMPED 3-PHASE PRODUCTION SEPARATORS.
  • Specialized Early Production Process Vessels
  • Up to 80,000BPD liquid handling capacity
  • Up to 100MMSCFD gas handling capacity
  • 8” gas line
  • 12” fluid inlet
  • 4” | 6” oil line
  • 3” | 4” water line
  • 4” dual relief system
  • Equipment with Hi-Lo pressure pilots
10,000PSI DUAL POT SAND FILTER
  • ASME SECTION VIII DIV. 2
  • NACE MR01-75
  • API 6A

MAX WORKING PRESSURE: 10,000PSI
WORKING TEMPERATURE: 20ºF-250ºF
MAX DRY GAS FLOW: 100-200MMSCFD
CODE STAMPING: NONE
Footprint: L:2976mm
B:2380mm

200BBL 150PSI ASME-U STAMPED VERTICAL PRODUCTION SURGE VESSEL
  • 6” oil inlet
  • 10” oil outlet
  • Measures liquid flow rates, shrinkage and meter factors
  • Level monitoring by sight glass or magnetic indicators
  • Access for internal inspection and maintenance
  • High- and low-level alarm system.
10,000PSI CHOKE MANIFOLD
  • Service H2S service per NACE MR01-75
  • Flow capacity 3-1/16” bore
  • Design pressure 10 000 psi
  • Design temperature -29°C to +121°C (-20°F to +250°F)
  • Codes of construction API-6A
  • Maximum choke Size is 2”
  • Flow line inlet 3” wing union fig. 1502 female
  • Flow line outlet 3” wing union fig. 1502 male
ELECTRO-HYDRAULIC EMERGENCY SHUTDOWN SYSTEM
  • Air driven hydraulic pump with two outlets.
  • Two stage back-up hydraulic pump, manually operated.
  • Hydraulic oil tank.
  • Well closure can be initiated from ESD panel or remote pull-button stations located at different places.
  • It can trigger an additional standalone hydraulic valve mounted anywhere in the flow stream.
BURNER ROOM
  • Modular boom can be easily configured as 60- or 90-ft units
  • Lightweight design reduces crane capacity restrictions and simplifies installation
  • Integral air, water, and vent lines reduce weight and piping congestion.
  • Protected walkway for added safety
  • Design of Service software package is used to predict heat radiation and noise levels during flaring of hydrocarbons under different environmental conditions to determine whether the radiant heat levels have been reduced to satisfactory levels.
10,000PSI DATA HEADER
  • NACE MR01-75 Short-sub connected along the process for sampling
  • 3” 1502TH Inlet and 3” 1502WH
  • 6 ea ½” Sampling Taps
  • Presents safe taps for pressure, Temperature monitoring, Fluid sampling for properties determination
  • Parameter monitoring requiring process fluid intrusion
SURFACE SAFETY VALVE
  • Service H2S service per NACE MR01-75
  • Flow capacity 3-1/16” bore
  • Design pressure 10 000 & 5,000PSI
  • Design temperature -29°C to + 121°C (-20°F to +250°F)
  • Codes of construction API-6A
  • Hydraulically actuated
100BBL DUAL COMPARTMENT 150PSI SURGE VESSEL
  • ASME Section VIII DIV 1 Lat Rev.
  • NACE MR0175 Complaint
  • Automatic control valve on the gas outlet line maintains a constant pressure in the vessel
  • Protected against overpressure by multi safety relief system
  • Bypass manifold allows isolating Protected against overpressure by multi safety relief system.
CRUDE TRANSFER & EXPORT PUMPS
  • Compliance with API 601 and ASME B31.3
  • Compliance with EExd IIB T4 if electrical drive Can be used in remote locations and in Zone 2 regions.
  • Protected against overpressure by a relief bypass valve.
  • Process crude transfer.
  • Reinjection processes
SURFACE TEST TREE/ FLOW HEAD
  • Service H2S service per NACE MR01-75 Design pressure 10 000 psi
  • Flow wing valve action Fail close
  • Closing time < 15 sec. (when connected to an ESD system)
  • Bottom saver sub 4 ½” IF thread (pin)
  • Top lift sub 5 ¾” – 4 ACME (box) Otis
PRESSURIZED/NONPRESSURIZED FIELD LABORATORY CABIN

Equipped with a full set of field petroleum analytical apparatus, allowing infield analysis of natural gas, liquid petroleum, and water:

  • Ranarex Gas Gravitometer
  • Complete range of hydrometers
  • Pressure/temperature transmitters
  • Electric centrifuge machine with heat bath
  • Deadweight tester
  • Draeger gas test kit
  • Refractometer
  • Measuring Cylinders
  • PH Paper
  • Salinity kit
  • Pressure and Differential Recorders etc.